Attributes
| Cycle Time |
3s |
| ESD |
Yes |
| Gross weight |
0.99kg |
| Material information |
Housing: Aluminum, hard anodized,Stop: Steel, hardened |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 12 m/min |
60 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 15 m/min |
55 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 18 m/min |
50 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 6 m/min |
100 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 9 m/min |
70 kg |
| Min. workpiece pallet weight m |
6 kg |
| Net weight |
0.99kg |
| Operating temperature [T] max |
+5 ... +60 °C |
| Required accessories |
Actuator and sensor system cables common in the market (5-pole) |
| Weight |
0.99kg |
| Workpiece pallet weight [mG] |
100kg |
- To the workpiece pallet separation in sections
- Dampened stop gate
- Can be combined with WT 2, WT 2/E, WT 2/F, WT 2/LS
- Can be combined with all TS 2plus components (except for HD components)
- Air damping adjustable by means of throttle screw
- Damping effect adjustable on the upper surface
- If the damping is set, weights of ± 50% of the set weight can be properly damped
- Loading only in the direction of transport
- No spring return, the stop blade of the stop gate is reset or put up by means of a step motor
- Electrical stop gate for the set-up of plants without pneumatic system
- Little installation work as there is no pneumatic system
- Low noise development
- Notice: A workpiece pallet may only hit the stop if the latter is completely in its top position
- - To the workpiece pallet separation in sections
- - Dampened stop gate
- - Can be combined with WT 2, WT 2/E, WT 2/F, WT 2/LS
- - Can be combined with all TS 2plus components (except for HD components)
- - Air damping adjustable by means of throttle screw
- - Damping effect adjustable on the upper surface
- - If the damping is set, weights of ± 50% of the set weight can be properly damped
- - Loading only in the direction of transport
- - No spring return, the stop blade of the stop gate is reset or put up by means of a step motor
- - Electrical stop gate for the set-up of plants without pneumatic system
- - Little installation work as there is no pneumatic system
- - Low noise development
- - Notice: A workpiece pallet may only hit the stop if the latter is completely in its top position
Stop gate VE 2/D100-E
To the workpiece pallet separation in sections, Dampened stop gate, Can be combined with WT 2, WT 2/E, WT 2/F, WT 2/LS, Can be combined with all TS 2plus components (except for HD components), Air damping adjustable by means of throttle screw, Damping effect adjustable on the upper surface, If the damping is set, weights of ± 50% of the set weight can be properly damped, Loading only in the direction of transport, No spring return, the stop blade of the stop gate is reset or put up by means of a step motor, Electrical stop gate for the set up of plants without pneumatic system, Little installation work as there is no pneumatic system, Low noise development, Notice: A workpiece pallet may only hit the stop if the latter is completely in its top position