Attributes
| Cycle Time |
3s |
| ESD |
Yes |
| Gross weight |
0.99kg |
| Material information |
Housing: Aluminum, hard anodized,Stop: Steel, hardened |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 12 m/min |
60 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 15 m/min |
55 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 18 m/min |
50 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 6 m/min |
100 kg |
| Maximum permissible mass workpiece pallet mG at nominal speed vN 9 m/min |
70 kg |
| Min. workpiece pallet weight m |
6 kg |
| Net weight |
0.99kg |
| Operating temperature [T] max |
+5 ... +60 °C |
| Required accessories |
Actuator and sensor system cables common in the market (5-pole) |
| Weight |
0.99kg |
| Workpiece pallet weight [mG] |
100 |
- To the workpiece pallet separation in sections
- Dampened stop gate
- Can be combined with WT 2, WT 2/E, WT 2/F, WT 2/LS
- Can be combined with all TS 2plus components (except for HD components)
- Air damping adjustable by means of throttle screw
- Damping effect adjustable on the upper surface
- If the damping is set, weights of ± 50% of the set weight can be properly damped
- Loading only in the direction of transport
- No spring return, the stop blade of the stop gate is reset or put up by means of a step motor
- Electrical stop gate for the set-up of plants without pneumatic system
- Little installation work as there is no pneumatic system
- Low noise development
- Notice: A workpiece pallet may only hit the stop if the latter is completely in its top position
- 1 - To the workpiece pallet separation in sections
- 2 - Dampened stop gate
- 3 - Can be combined with WT 2, WT 2/E, WT 2/F, WT 2/LS
- 4 - Can be combined with all TS 2plus components (except for HD components)
- 5 - Air damping adjustable by means of throttle screw
- 6 - Damping effect adjustable on the upper surface
- 7 - If the damping is set, weights of ± 50% of the set weight can be properly damped
- 8 - Loading only in the direction of transport
- 9 - No spring return, the stop blade of the stop gate is reset or put up by means of a step motor
- 10 - Electrical stop gate for the set-up of plants without pneumatic system
- 11 - Little installation work as there is no pneumatic system
- 12 - Low noise development
- 13 - Notice: A workpiece pallet may only hit the stop if the latter is completely in its top position
Stop gate VE 2/D100-E
To the workpiece pallet separation in sections, Dampened stop gate, Can be combined with WT 2/E, WT 2 and WT 2/F, Can be combined with all TS 2plus components (except for HD components)